Where the Bradford White RG140T6X fits
The RG140T6X is a 40-gallon nominal tall propane (LP) water heater in Bradford White’s standard Atmospheric Vent Gas family. The narrower 40-gallon tall version has an 18-inch jacket and 38 gallons of rated storage. It offers a different fit from RG240T6: less width, but a higher heater top and exhaust connection. That tradeoff matters in a narrow closet with overhead piping.
This model’s published first-hour rating is 64 gallons. Discuss the busiest period of hot-water use, including closely spaced showers or a large tub, when deciding whether it is adequate. A 40-gallon label by itself does not establish that two replacement candidates deliver the same amount of hot water in the first hour.
Capacity, first-hour delivery and efficiency
The current U.S. specification lists 40 gallons nominal capacity, 38 gallons DOE rated storage, a 64-gallon first-hour rating and 0.59 UEF for this model row. Nominal capacity is the listed size category; rated storage is the separately published stored volume. First-hour rating combines stored hot water with reheating during a standardized hour.
UEF is a standardized efficiency measure, not a prediction of your bill or a substitute for checking hot-water demand. The sheet uses N-suffix base rows and directs the final N to be changed to X for propane. It gives one first-hour and UEF pair per row, with separate LP input and recovery columns; this guide uses those LP columns.
Dimensions and connection heights
- A — floor to exhaust connection: 61 5/16 inches.
- F — floor to top of heater: 57 13/16 inches.
- B — jacket diameter: 18 inches; H — depth: 21 1/2 inches.
- G — floor to water connections: 59 9/16 inches; J — center spacing: 8 inches.
- M — water connections: 3/4-inch NPT.
- D — floor to standard side T&P connection: 51 5/8 inches.
- S — gas connection: 1/2 inch, located 13 inches above the floor.
- Approximate shipping weight: 132 pounds, not the filled operating weight.
The exhaust connection is 61 5/16 inches above the floor, and the water connections are at 59 9/16 inches. Those dimensions differ from the wider 40-gallon version. A smaller diameter does not mean that every measurement is smaller, especially when reconnecting an existing vent.
These are equipment dimensions, not installation clearances. Allow space for the pan, fittings, relief discharge and access to the controls, drain and anode. The selected tall models have an optional top T&P location that must be specified when ordering; this guide uses the standard side arrangement.
Compare the other tall options
The RG240T6X is the wider 40-gallon tall alternative. It lists a 20-inch jacket, 38 gallons rated storage, a 75-gallon first-hour rating and 0.64 UEF. For propane (LP), its published input is 36,000 BTU/h and recovery is 34 GPH at a 90°F rise. Compare those figures with this model’s 18-inch jacket and 64-gallon first-hour rating.
For another storage size in the same fuel, review the RG150T6X 50-gallon tall guide. The RG140T6N is the corresponding natural gas model. Choose the correct fuel first, then compare storage, delivery and fit.
Propane (LP) input and recovery
The published propane (LP) input is 34,000 BTU/h, with 37 gallons per hour recovery at a 90°F temperature rise. Recovery is separate from the first-hour rating and is not the amount stored in the tank. The required temperature rise and actual use affect how the heater replenishes hot water.
WHE checks the propane supply and regulator arrangement along with the other appliances served. The X-suffix heater must match the supplied fuel; the manufacturer identifies a separate propane burner. A matching tank size is not a reason to connect a natural gas model to propane. The 1/2-inch appliance connection does not establish the required supply-pipe size.
Atmospheric venting and installation scope
The specification lists a 3- or 4-inch vent connection for this input range. That does not mean either size is suitable for every installation. WHE reviews the vent route, condition, draft arrangement, combustion air and any commonly vented appliances. A power-vent or direct-vent heater has different requirements and is not an automatic replacement match.
This is an indoor storage heater. The estimate considers access, old-unit removal, supporting surface, shutoffs, piping, drainage, relief discharge and expansion control where the water supply is closed. If the current heater is difficult to reach in an attic, we can assess whether moving it to a garage is practical.
Features, care and six-year warranty
This family includes the Defender flammable-vapor ignition resistant system, a protective anode and sediment-control features. The sheet describes an ICON gas control that needs no external electricity, with controls subject to regional variation. These features do not make the tank maintenance-free. Keep service access clear and have internal gas-system diagnosis performed by a qualified professional.
The 6 identifies the six-year tank version. For qualifying single-family use, the residential certificate provides six-year limited tank and parts terms. Other residential use of this six-year model has one-year terms; nonresidential or commercial use is excluded. Removal, installation and associated repair or replacement costs are excluded, subject to applicable law. Retain the supplied certificate, model, serial number and installation record.
Official documents and image note
Checked October 17, 2026 against the current U.S. Atmospheric Vent Gas family, 1101-1125 specification (November 2025), 238-51012-00V installation manual (August 2026) and 238-39699-00ZAN residential warranty (March 2025). The official family photograph is representative; proportions, labels and fuel-specific components vary. The supplied nameplate and documents establish the exact equipment.
Plan your Bradford White replacement
Explore our Bradford White installation options, gas water heater service and model catalog. Water Heating Experts is family owned and master plumber owned, serving Palm Beach Gardens, Jupiter and nearby Palm Beach County communities under Florida license CFC1426133. Call 561-602-9062, text site photos or request a free installation estimate. Price, availability and scheduling are confirmed for your project.
Bradford White RG140T6X FAQs
Does RG140T6X store 40 gallons?
The current row lists 40 gallons nominal and 38 gallons DOE rated storage. Its 64-gallon first-hour figure includes reheating during the test; it is not stored volume.
How does RG140T6X differ from RG240T6X?
RG140T6X has a 18-inch jacket and a 64-gallon published first-hour rating. RG240T6X has a 20-inch jacket and a 75-gallon rating. Compare the fuel-specific input, recovery and full installation footprint too.
Is RG140T6X natural gas or propane?
This guide covers propane (LP). Bradford White uses N for the natural gas version and X for propane. Confirm the complete model and supplied fuel before installation.
Can WHE reuse my existing vent?
Only after checking its size, condition, route and suitability for the proposed equipment and any commonly vented appliances. The listed appliance connection alone does not establish that the existing vent is suitable.
What should I send for an estimate?
Send the existing model label, a wide installation photo, available opening measurements and your hot-water concerns. Online booking starts the estimate; WHE confirms equipment availability and scheduling afterward.