Tempra 15 Plus: capacity and installation fit
The Tempra 15 Plus combines two-circuit electric tankless heating with the Plus family’s automatic flow control and expanded display. Its model name should not be read as an exact power rating: the published input is 14.4 kW at 240 V. It is a step above the 12 Plus for projects whose demand justifies the additional output.
This guide covers Stiebel Eltron Tempra 15 Plus, item 239220. It is an electric tankless water heater, with output determined by power and temperature rise rather than stored gallons. Water Heating Experts helps Palm Beach Gardens, Jupiter and nearby homeowners assess the model and the work needed to install it. See our Stiebel Eltron overview for the family comparison.
What the Plus controls add
The Tempra 15 Plus includes Advanced Flow Control. If demand exceeds the available heating capacity, it can reduce water flow to maintain the selected outlet temperature. It also has two temperature memory presets and a display showing flow rate and operating capacity. These are useful controls, but the model still needs enough output for the way you want to use hot water.
The Tempra 15 Trend has the same published heating input at each voltage. Plus adds flow management and display functions rather than a higher kW rating. Both families modulate heating power. Choosing Plus therefore involves deciding how you want the heater to respond near its capacity limit, as well as selecting the correct size.
Electrical requirements: 240 V versus 208 V
| Specification | 240 V | 208 V |
|---|---|---|
| Rated input | 14.4 kW | 10.8 kW |
| Maximum current draw | 2 × 30 A | 2 × 26 A |
| Manufacturer minimum recommended double-pole breakers | 2 × 30 A | 2 × 30 A |
| Minimum recommended copper wire runs | 2 × 10/2 AWG | 2 × 10/2 AWG |
The manufacturer recommends a 100 A minimum main service, depending on total electrical load. This is separate from the branch-circuit requirements. The standard ratings are for single-phase, 50/60 Hz supply; the manual also addresses applicable 208 V three-phase arrangements for certain sizes. A qualified electrician must confirm the actual supply and design the installation for the specific model.
Stiebel Eltron specifies copper conductors rated at least 75°C and sizing for less than 3% voltage drop under load. Existing tank-water-heater wiring cannot be assumed suitable. Include the home’s other major loads and planned electrical additions in the assessment. These comparison figures are not directions to change breakers or conductors yourself.
Flow examples with stated water temperatures
Compared at the same water temperatures, this model provides more flow than the 12 Plus, but it remains one of the lower-output Tempra options. A household that usually uses one shower at a time may have a different requirement from one that expects a shower, sink and appliance to overlap. Identify that pattern before deciding whether the 15 Plus is enough.
| Inlet → outlet temperature | Manufacturer 220–240 V row | 208 V |
|---|---|---|
| 77°F → 113°F (36°F rise) | 2.72 GPM | 2.04 GPM |
| 59°F → 113°F (54°F rise) | 1.82 GPM | 1.36 GPM |
These are the manufacturer’s published flow-table examples. Its higher-output rows are labeled 220–240 V; electrical input in our specification table is specifically stated at 240 V. The example inlet temperatures are not a measurement of your home. Higher requested outlet temperatures or colder inlet water reduce available flow.
List the showers, faucets and appliances you expect to operate together. Fixture flow and overlap matter more than bathroom count alone. Water at a mixed faucet can also have a different flow from water passing through the heater. Tell us which uses your current system struggles to support so we can compare the replacement against a concrete demand.
Dimensions, efficiency and service access
The current technical data table lists 0.96 UEF, a minimum activation flow of 0.50 GPM and a weight of 16.1 lb. Cabinet dimensions are 16⅝ inches wide × 14½ inches high × 4⅝ inches deep, with ¾-inch NPT water connections. UEF is a standardized comparison value, not a promise of a particular bill reduction.
Allow the manual’s 5 inches of service clearance on all sides, along with room for connections. Plan a protected location away from freezing and routine splashing. Accessible plumbing matters for future maintenance, including attention to scale and the inlet screen. The installation manual is the reference for the installer’s final layout.
Keep the receipt and installation record and follow the supplied registration directions. The manufacturer’s limited warranty lists seven years for qualifying leakage and three years for qualifying defects, subject to its terms; field labor is not included. Discuss water quality and maintenance needs when planning the installation.
Compare nearby sizes before deciding
The 12 Plus uses a single circuit, while the 15 Plus and 20 Plus use two. The 20 Plus raises the 240 V input to 19.2 kW and changes the recommended circuit sizes. If you are comparing these models, look at the complete electrical scope and the colder-water flow case alongside the convenience of the Plus controls.
Read the Tempra 12 Plus and Tempra 20 Plus guides, compare the matching Trend model above, or browse the full water-heater model catalog. If electrical changes affect the project significantly, compare a suitable electric storage water heater as part of the complete installation estimate.
Tempra 15 Plus questions
Why does the Tempra 15 Plus specification say 14.4 kW?
Tempra 15 Plus is the model name. Its actual rating is 14.4 kW at 240 V or 10.8 kW at 208 V. Use those voltage-specific values when assessing the electrical load and comparing performance.
Does Advanced Flow Control increase heating output?
No. It manages water flow when demand exceeds the heater’s available capacity. Reducing flow helps maintain temperature, but it cannot supply the same high flow as a larger heater under every condition. Select the model for the simultaneous demand you want it to handle.
Does the Tempra 15 Plus have temperature presets?
Yes. Tempra Plus has two stored temperature presets, along with a flow-rate display. Presets make an existing setting easier to recall; they do not change the unit’s maximum heating capacity or resolve an undersized installation.
Will tankless eliminate the wait at distant taps?
Water already in the pipe must still travel to the fixture. Heater output, pipe length and any recirculation arrangement are separate considerations. Tell WHE which taps have long waits so the estimate addresses that concern specifically.
What information helps with an installation estimate?
Send the current heater’s label, a wide installation photo, your location and a description of simultaneous hot-water use. Mention Tempra 15 Plus. We review the plumbing and electrical requirements before confirming equipment availability, the proposed work and scheduling.
Request a Tempra 15 Plus installation estimate
For water-heater installation or replacement, call 561-602-9062, text WHE or request a free installation estimate. Share the project details so we can discuss a suitable model and installation scope.
Sources checked October 17, 2026: Tempra Plus family information and Tempra technical specifications, revision 6.2025, with the manufacturer manual, flow table and warranty linked above. Confirm the exact unit label and current installation documents before work begins.