Family owned · Master plumber owned · Palm Beach County · Florida license CFC1426133

← Browse water heaters

American VSCE62-119R 250 119-Gallon Light-Service Commercial Electric Water Heater

A 119-gallon nominal commercial tank with 108 gallons rated storage. Requires 277V single-phase supply; 12.2 kW simultaneous input. Listed warranty: six-year tank and one-year parts.

Family-owned · Master plumber-owned
Florida license CFC1426133

Available through WHE with professional installation only. Every installation is quoted individually. Mention this model in your request; we confirm equipment availability and installation requirements before providing an estimate. Serving Palm Beach Gardens, Jupiter and nearby Palm Beach County communities.

American VSCE62 light-service commercial electric water heater, shared manufacturer series image; dimensions vary by capacity
American manufacturer representative image shared by the VSCE62-65R 250, VSCE62-80H 250 and VSCE62-119R 250 product pages. Body dimensions and proportions vary by capacity.

Model specifications

Model
VSCE62-119R 250
Heater type
Storage tank
Energy source
Electric
Capacity
119-gallon nominal capacity; 108-gallon rated storage
Dimensions and clearances
Drawing A: 61½ inches high × C: 28 inches diameter; B: 54½ inches to T&P valve center. Allow additional plumbing, pan and service space.
Efficiency
98% thermal efficiency (not UEF). 277V single phase; 12.2 kW total simultaneous input; 44.04A listed load. Recovery: 56 GPH at a 90°F rise in the 2024 manual; older sheet lists 50 GPH.

View manufacturer specifications

Is the VSCE62-119R 250 right for your application?

The American VSCE62-119R 250 is the largest model in this light-service commercial range. It lists 119 gallons nominal capacity and 108 gallons of rated storage. Its 61½-inch height is close to the smaller models, but the 28-inch diameter makes floor space and the access route especially important.

This is a 277V, single-phase, 12.2 kW commercial configuration. Electrical compatibility is a key part of choosing it; an existing 240V water-heater circuit is not a direct match.

The larger reserve can help with a substantial intermittent draw when there is enough time for recovery afterward. WHE checks peak usage and the interval between loads before recommending this size. More storage does not increase the series’ 12.2 kW heating input or its listed recovery rate.

American VSCE62-119R 250 specifications

Exact model / product item VSCE62-119R 250 / 100298906
Nominal capacity / rated storage 119 gallons / 108 gallons
Type / installation Light-service commercial electric storage tank / indoor
Electrical supply 277V, single phase, 60Hz
Elements / total input Two 6.1 kW elements; simultaneous operation; 12.2 kW total
Product-page current rating 44.04 amps — equipment load, not a breaker-size recommendation
Thermal efficiency 98% listed on the product page; this is not a UEF rating
Recovery at a 90°F rise 56 GPH in the June 2024 Series 250 manual; older specification sheet lists 50 GPH — see note below
Drawing A: height / C: diameter 61½ / 28 inches
Drawing B: T&P valve center height 54½ inches
Water connections / drawing D Top ¾-inch inlet and outlet / 8-inch centers
Maximum working pressure 150 psi
Insulation blanket included No
Listed limited warranty 6 years tank / 1 year parts, subject to the applicable certificate

The product page and series sheet identify a 119-gallon nominal model; the shared installation manual groups the largest size under a 120-gallon heading. Rated storage for this exact product is 108 gallons. Match the VSCE62-119R 250 nameplate rather than substituting specifications from a different 120-gallon heater.

Electrical supply and installation planning

The series is factory wired for simultaneous operation, so both 6.1 kW elements contribute to the 12.2 kW connected load. WHE verifies the actual nameplate, available voltage and electrical installation requirements before confirming equipment. The installation manual calls for a separate grounded branch circuit, over-current protection and a disconnect; a qualified electrical professional determines the required circuit and conductor sizes.

The body dimensions do not include every part of the installation space. Allow for the drain pan, top piping and electrical connection, relief discharge, anode removal and access to both front panels. The manual calls for at least four inches of access to replaceable parts and enough additional room for servicing. WHE also checks full-tank support, water pressure, thermal expansion and the drainage route.

The thermostat’s listed adjustment range is approximately 120–181°F. That is an equipment capability, not a recommended delivery temperature. The application may require temperature control and thermostatic mixing valves to keep fixture temperatures safe; higher storage settings need a complete system review.

Recovery rating and document differences

The June 2024 Series 250 manual lists 56 gallons per hour at a 90°F rise for simultaneous 6,100W/6,100W operation. The older April 2022 NCESS00116 sheet lists 50 GPH at that same rise. This guide uses the newer manual for comparison and flags the disagreement so the required output can be confirmed before sizing a job.

A temperature rise is the difference between entering water temperature and the target water temperature. More rise reduces hourly recovery. Rated storage, recovery and first-hour delivery are different measurements; these sources do not provide a first-hour rating for this exact product. Likewise, 98% thermal efficiency should not be treated as a UEF score when comparing it with residential tanks or heat-pump models.

Compare the three American light-service sizes

Model Nominal / rated storage Height × diameter Supply / total input
VSCE62-65R 250 66 / 59.5 gal 60¼ × 22 in. 277V / 12.2 kW
VSCE62-80H 250 80 / 72 gal 60½ × 24 in. 277V / 12.2 kW
VSCE62-119R 250 119 / 108 gal 61½ × 28 in. 277V / 12.2 kW

This model adds 36 gallons of rated storage over the 80-gallon version. The body is only one inch taller, but four inches wider. Compared with the 66-gallon option, it adds 48.5 gallons of rated storage and six inches of diameter, so access and full-tank support need careful review.

All three share the same listed 277V supply, 12.2 kW input and recovery table. Moving to a larger size adds stored reserve. It does not increase the heating input or the published recovery rate.

Maintenance and limited warranty

The series uses a glass-lined tank, anode protection, zinc-plated copper-sheathed heating elements and a brass drain valve. Keep the service panels, drain valve and anode accessible. Flushing, scale control and anode inspection should follow the manual and the site’s water conditions.

The current product page and series sheet list six years of limited tank coverage and one year for parts. The warranty download supplied on the page carries VSCE32 model names in its heading, while this product is VSCE62. Confirm the applicable certificate for the exact supplied unit. The linked terms exclude service labor, installation, shipping and other related costs; six-year tank coverage does not mean six-year parts or labor coverage.

Manufacturer sources and local installation

Sources checked October 17, 2026: the official VSCE62-119R 250 product page, NCESS00116 light-service specification sheet, Series 250 installation and service manual 100380318 and linked light-service limited warranty. American uses the same representative photograph for all three capacities; actual dimensions vary.

For a Palm Beach County replacement, send WHE the current model and electrical nameplate, photos of the piping and surrounding space, and a description of the busiest hot-water demand. Visit our American water heater installation page and water heater model catalog.

American VSCE62-119R 250 FAQs

Is this the 119-gallon or 120-gallon model?

The exact product is VSCE62-119R 250, listed at 119 gallons nominal and 108 gallons rated storage. The shared manual calls the largest size 120 gallons. Use the complete model and electrical rating to identify the supplied heater.

Can it use my existing 240V water-heater circuit?

The linked configuration is rated 277V single phase with 12.2 kW connected input. It is not a direct 240V replacement. WHE and the electrical professional must verify the supply and exact equipment nameplate before selecting the heater.

What recovery rate should I use?

The June 2024 Series 250 manual lists 56 GPH at a 90°F rise; the April 2022 sheet lists 50 GPH at that rise. This guide identifies both and uses the newer manual for comparison. Confirm the required output for the actual application before ordering.

Will a larger size recover hot water faster?

These three models share the same 12.2 kW input and recovery table. The larger tank provides more stored reserve; it does not increase the published hourly recovery rate.

Does the six-year warranty cover parts and labor?